5.3.3 APPX Application Design Manual

+ Chapter 1-1: Overview of Application Design
+ Chapter 1-2: Getting Started
+ Chapter 1-3: Data Dictionary
+ Chapter 1-4: Understanding Process Design
+ Chapter 1-5: Interprocess Communication
+ Chapter 1-6: Customizing Your Application
+ Chapter 1-7: The Documentation Facility
+ Chapter 1-8: Application Design Tools
+ Chapter 2-1: Data Dictionary Overview
+ Chapter 2-2: Data Dictionary Concepts
+ Chapter 2-3: Domains
+ Chapter 2-4: Files and Fields
+ Chapter 2-5: Work Fields
+ Chapter 3-1: Overview of APPX Processes
+ Chapter 3-2: Getting Started
+ Chapter 3-3: Process Definition
+ Chapter 3-4: Menu Processes
+ Chapter 3-5: Job Processes
+ Chapter 3-6: Input Processes
+ Chapter 3-7: Output Processes
+ Chapter 3-8: Update Processes
+ Chapter 3-9: Query Processes
+ Chapter 3-10: Inquiry Processes
+ Chapter 3-11: Status Processes
+ Chapter 3-12: Subroutine Processes
+ Chapter 3-13: Table Processes
+ Chapter 3-14: Automatic and Optional Children
+ Chapter 3-15: Using the Image Editor
+ Chapter 3-16: Using GUI Features of the Image Editor
+ Chapter 3-17: Using Event Points
+ Chapter 4-1: ILF Integration
- Chapter 4-2: True/False Status Indicators
+ Chapter 4-3: Specifying Statements
+ Chapter 4-4: The ILF Editor
+ Chapter 4-5: The Appx ILF Debugger
+ Chapter 4-6: ILF Keyword Reference
+ Chapter 4-7: Predefined Fields
+ Chapter 4-8: Runtime Subroutine's and Predefined Processes
+ Chapter 4-9: Appx Chart Director API

Chapter 4-2: True/False Status Indicators

Using AND After an IF Statement


Consider the following example using an AND statement after an IF. In this example, the two statements are really part of a single logical verification since your intent is to check if both of the two statements are true.

          IF   TAR CUSTOMER BALANCE   GT 0
          AND  TAR WORK ON ACCOUNT AMOUNT NE 0

When the IF statement executes, it automatically sets the level 1 true/false status indicator to either T or F, as appropriate.

If the IF statement is false, setting level 1 to F, the AND statement is bypassed because the possibility that both conditions are true has already been eliminated.

If the IF statement is true, the AND statement executes. If the AND statement is true, the level 1 indicator is preserved (left unchanged as T). If the AND statement is false, the level 1 indicator is changed to F.

Application Design Manual                                         "Powered by Appx Software"

529

©2006 By APPX Software, Inc. All Rights Reserved